Yaskawa CM013 User Manual
V7 devicenet™ with adr option kit cm013, Warning

V7 DeviceNet™ With ADR Option Kit
CM013
Yaskawa Electric America, Inc. –
www.yaskawa.com
IG.V7.16, Page 1 of 8
Date: 06/15/2007 Rev: 07-06
1. Applicable products: Standard V7 drives CIMR-V7AM*) with
Communication specific software installed (not V74X or V7N). Check V7
keypad monitor U-10 or the PRG # on the V7 nameplate for version 8340
or 8350 software.
Note: To order a V7 with Communication specific software, use the following
part number format: CIMR-V7AM****1-057.
2. When using this Kit, it is strongly recommended that no connections be
made to the V7 drive's DC Bus terminals (+1 and -) on models CIMR-
V7AMxxxx1, where xxxx is 25P5, 27P5, 45P5, or 47P5. A connection for
a DC reactor (+1 to +2) or braking resistor (B1 to B2) is allowed.
3. Unpack the V7 DeviceNet Option Kit CM013 and verify that all
components are present and undamaged.
4. Connect power to the Yaskawa V7 Drive and verify that it functions
correctly.
This includes running the V7 from the operator keypad. Refer to the V7 Drive
Technical Manual, TM.V7.01, for information on connecting and operating
the V7 drive.
5. Remove power from the V7 and wait for the charge lamp to be
completely extinguished. Wait at least five additional minutes for the V7
to be completely discharged. Measure the DC bus voltage and verify that
it is at a safe level.
6. Remove the operator keypad and V7 drive cover.
a. Remove the terminal cover by removing the retaining screw and lifting
out the cover.
b. Remove the operator keypad.
7. Remove the CN2 cover from the V7 drive housing. Carefully snip the 3
tabs connecting the CN2 cover to the V7 housing and remove the cover.
8. Attach the Mounting Bracket. Align the mounting bracket as shown in the
figure to the right. Secure the mounting bracket to the V7 drive housing using
the M3x8 screw provided.
DeviceNet Option Kit CM013 Kit Parts
Qty.
V7 DeviceNet Option Ring Kit
(72606-EZZ08465 ring kit containing UTC000180 card)
1
Option Mounting Bracket
1
Mounting Bracket Screw (M3x8)
1
Ferrite (Power & Motor Leads) (Steward 28A5776-0A2)
2
Cable Ties (UWS-0137)
2
6” Ground Wire (150mm)
1
8.5” Ground Wire (220mm)
1
12.5” Ground Wire (320mm)
1
Installation Guide (IG.V7.16)
1
WARNING
Dangerous voltages in excess of 400VDC (230V drives) or 800VDC
(460V drives) are present at the DC bus terminals of the drive.