Yaskawa F7 Drive 1500 Hz Output User Manual
Page 4

Date: 05/05/05, Rev: 05-05
Page 4 of 7
TM.F7SW.056
4.3 Modified Parameters and Functions
Parameter
Number
Description
A1-02
Motor 1 Control Method: Setting fixed to ‘0’ (Open Loop V/F)
B3-01
Speed Search Selection: Range changed to 2 ~ 3
B5-15
PID Sleep Level: 1000.0Hz maximum
B6-01
Dwell Frequency at Start: 1000.0Hz maximum *1
B6-03
Dwell Frequency at Stop: 1000.0Hz maximum *1
C1-11
Acc/Dec Switch Frequency: 1000.0Hz maximum *1
C4-01
Torque Compensation Gain: Default changed to 0.0
C6-03
Carrier Frequency Upper Limit: 10.0kHz maximum and default
C6-04
Carrier Frequency Lower Limit: 10.0kHz maximum and default
D1 Group
Frequency References: 1000.0Hz maximum *1
D3-01
Jump Frequency 1: 1000.0Hz maximum *1
D3-02
Jump Frequency 2: 1000.0Hz maximum *1
D3-03
Jump Frequency 3: 1000.0Hz maximum *1
D6-02
Field Weakening Frequency: 1000.0Hz maximum *1
E1-04
Motor 1Maximum Output Frequency: 1000.0Hz maximum *1
E1-06
Motor 1 Base Frequency: 1000.0Hz maximum *1
E1-07
Motor 1 Midpoint Frequency A: 1000.0Hz maximum *1
E1-09
Motor 1 Minimum Frequency: 1000.0Hz maximum *1
E1-11
Motor 1 Midpoint Frequency B: 1000.0Hz maximum *1
E3-01
Motor 2 Control Method: Range fixed to 0 (Open Loop V/F)
E3-02
Motor 2 Maximum Output Frequency: 1000.0Hz maximum *1
E3-04
Motor 2 Base Frequency: 1000.0Hz maximum *1
E3-05
Motor 2 Midpoint Frequency A: 1000.0Hz maximum *1
E3-07
Motor 2 Minimum Frequency: 1000.0Hz maximum *1
F3-01
DI-08 / DI-16H2 Selection: Range changed to 0 ~ 4, 7
L4-01
Speed Agree Level: 1000.0Hz max *1
L4-03
Speed Agree Level +/-: -1000 to 1000Hz max *1
N1-01
Hunting Prevention Selection: Default changed to 0 (Disabled)
O1-03
Keypad Display Scaling: Setting ‘0’ resolution changed to 0.1Hz
*1: 1500Hz when C6-11 = 1 (Frequency Reference Limit).