Refer to Sheet 1 for latest change.

DWG. NO. 02Y00025-0393
SHEET NO. 8 OF 10
R E L . 4 / 2 6 / 9 6

• • •

T1

T2

T3

R

S

T

U

V

W

GPD 503,
VCD 703,

or GPD 515

CONTROL

PCB

3

11

B0/–

B1/+

BRAKING

UNIT #1

B

P

N

3

1OL

1M

1M

1M

CB

L1

L2

L3

BRAKING

RESISTOR

UNIT

1

2

1THG

B

P

P

o

(E)

4

[ N/– ]

[ P1 ]

INDICATES VCD 703 TERMINAL MARKING,
INDICATES GPD 515 TERMINAL MARKING,
WHEN DIFFERENT FROM GPD 503

[XX]

PART OF
EXTERNAL
CIRCUIT

120VAC

THRX

FAULT

CONTAC

T

THRX

RC

1M

RC

1M

THRX

POWER

ON

POWER

OFF

1

2

NOTE:
CONNECT ONLY THE NUMBER
OF BRAKING UNITS AND BRAKING
RESISTOR UNITS REQUIRED FOR
THE APPLICATION.

GND

MASTER

5

6

BRAKING

UNIT #2

B

P

N

3

1OL

BRAKING

RESISTOR

UNIT

1

2

1THG

B

P

P

o

(E)

4

GND

• • •

SLAVE

5

6

1

2

1
2

(XX)

( – )

( + 3)

4

3

N

P

2 1

TO ADDITIONAL

BRAKING

RESISTOR UNIT(S),

IF PRESENT

TO ADDITIONAL

BRAKING UNIT(S),

IF PRESENT

TO NEXT

(SLAVE)

BRAKING

UNIT

1Fu*

1Fu*

*See UL/cUL Compliance information on sheet 1 of 10.

Figure 3. Wiring Multiple Braking Units and Braking Resistor Units to Drive