12 general specifications – Yaskawa Σ-II Series User Manual
Page 25
12 General Specifications
E-23
12 General Specifications
The following table shows the SERVOPACK general specifications.
Item
Specifications
Surrounding Air/Storage Tem-
perature
0 to +55
°C/-20 to +85 °C
Operating/Storage Humidity
90%RH or less (non-condensing)
Operating Environment
• Installation category (Overvoltage category): III
• Pollution degree: 2
• Protection class: 10
• Altitude: 1,000 m max.
Vibration Resistance
4.9 m/s
2
Shock Resistance
19.6 m/s
2
Voltage Resistance
• Voltage: 1,500 V rms AC, for one minute
• Braking current: 30 mA
• Frequency: 50 Hz or 60 Hz
• Voltage applied points
100 V and 200 V SERVOPACK: Between the frame ground
and the power where the terminals L1, L2, L3, L1C, L2C, U,
V, and W connect.
400 V SERVOPACK: Between the frame ground and the
power where the terminals L1, L2, L3, U, V, and W connect.
Insulation Resistance
10 M
Ω
min. (500 VDC megger) between the frame ground
and the power terminals U, V, and W
Overseas Standards
(Pending Approval)
• UL Standards: UL508C
• EMC Directives: EN61000-6-2, EN55011 (group 1 class A)
• Low Voltage Directive: EN50178