7 Troubleshooting

7

Troubleshooting

Preventing Noise Interference

Take the following steps to prevent erroneous operation caused by noise interference:

• Use shielded wire for the PG signal lines.

• Limit the length of all motor output power cables to less than 100 m.

• Separate the control wiring to the option, main circuit input power wiring, and motor

output power cables.

• Ground the shield on the PG side and the drive side. If noise problems arise in the PG

signal, verify that the shield is properly grounded and ground one end of the signal line or

remove the ground connection on both ends.

Interface Circuit

Figure 11

Figure 11 Interface Circuit

26LS32 level

26LS31 level

PGX3

PG

A,B,Z

A+,B+,Z+

600 Ω

a,b,z

a+,b+,z+

SG

Monitor Signal

A,B,Z

A,B,Z 26LS31 level