Electrical connections

Before connecting the appliance, check that the

voltage quoted on the rating plate - that is, the no-

minal voltage of the appliance - corresponds to

the available mains voltage. The rating plate can

be found on the base of the ceramic glass hob.

.

The mains connection must be carried out by an

expert electrician. The VDE-regulations and the

valid regulations by the electricity supply boards

have to be compiled with.

.

Prior to connection it should be checked whether

the voltage stated on the rating plate -- i.e. the

nominal voltage of the appliance -- is identical with

the mains voltage. The rating plate is located on

the base housing of the hob.

.

The heating element voltage is to 230 V ~. The

appliance will also perfectly perform with the lo-

wer mains voltage of 220 V ~.

.

The mains connection must be carried out in a

way that an all--pole insulating device is existing

with a contact opening of at least 3 mm, e.g. LS--

automatism, earth--leakage circuit--breaker or

fuse.

.

A wire of type H05VV-F or of higher rating is to be

used as supply cable.

.

The mains terminal is located in the bottom of the

appliance under a plastic cover. It can be opened

using a screwdriver (see picture).

.

Subject to the existing mains voltage, the ap-

pliance has to be connected as shown opposite.

The links of the terminal block must be changed

accordingly, if appropriate.

.

The earth conductor is to be connected to termi-
nal

. The earth conductor must be longer than

live leads.

.

The cable connections have to be connected

as shown and the terminal screws be firmly

tightened.

.

Afterwards the supply cable has to be secured by

the cable clamp and the cover must be fitted by

firmly pressing down until it engages.

Prior to first use remove any existing labels and

protective film from the ceramic glass plate or the

frame of the hob.

After connecting the electrical supply, all cooking

zones should be briefly switched on one after the

other at their maximum power, in order to test

whether they are operational.

strain relief device

Mains terminal

in the base of the hob

changing brid-

ges of the ter-

minal

L1

N

5

Connecting possibilities

1

2 3 4

L1

L2

N

5

1

2 3 4

L1 L2 L3

N

5

1

2 3 4

L1

L2

5

1

2 3 4

L1

L2 L3

5

1

2 3 4

(L3)

1 L + N

2 L + N

3 L + N

2 L

3 L

230 V

~

400 V

2 N

~

400 V

3 N

~

230 V

2

~

230 V

3

~

Read the installation instructions before con-

necting the mains cable. Ensuring that the

links are fitted correctly to the terminal block

UK only