beautypg.com

Checking the main oven – Electrolux ZCG5300 User Manual

Page 37

background image

37

Checking the main oven

1. Turn on the oven thermostat control

knob to mark 9 and press the ignition

button. As soon as the burner is alight

the button can be released.

2. There should now be a low gas rate to

the burner, which is the F.S.D bypass

rate.

3. When the F.S.D. phial has heated up it

opens the F.S.D valve which allows the

main gas supply to the oven burner.

4. After 1 minute check that the flame

covers the full width of the burner and is

stable.

5. Set the oven control to Mk 2, close the

oven door and check that after about 10

minutes the flame size has reduced.

6. Turn off the control and check that the

oven flames go out.

General note

Instruct the user on how to use the appliance

and its ignition system. Refer the user to the

wording on the inside cover which gives

advice on the safe operation of the

appliance.