Levelling the appliance

Adjustment to suit floor conditions or height

is obtained by rotating clockwise or anti

clockwise the feet at the front and rear of the

appliance. A spirit level should be placed on

one of the shelves to confirm the appliance

is correctly levelled.

Connecting to gas supply

This appliance is designed to be installed

with an appliance flexible connection only.

Supply piping should not be less than R

3

/8.

Connection is made to the Rc ½ (½” B.S.P.)

female threaded entry pipe located just

below the hotplate level on the rear left hand

side of the appliance.

NOTE: ONLY LIQUID

SEALANTS TO BE USED WHEN INLET

GAS PIPE IS FITTED I.E.: DO NOT USE

P.T.F.E. SEALANT TAPE. Carry out a gas

tightness test after connecting to the gas

supply. The gas bayonet connector must be

fitted in the shaded area indicated in Fig.2.

Take into account that it must be possible to

pull the appliance forward sufficiently.

Ensure the hose does not become trapped

when pushing the appliance into position.
IMPORTANT: FLEXIBLE TUBING USED

MUST COMPLY WITH BS.669 CURRENT

EDITION.
LPG Flexible connections must be a type

suitable for L.P.G and capable of operation

up to 50 mbar and carry a red stripe, band or

label.

Fig.2.