12.7 Gas
regulations
If the cooking appliance is set up for a different type of gas than that available, its injectors must
be replaced, the minimum flow regulated. In order to replace the injectors in the cooking hob, it is
necessary to carry out the following operations:
• remove the pan supports;
• remove the burners and burner caps (Fig. A);
• take out the injector (Fig. B) and replace it with one
suitable for the new type of gas (see "G
ENERAL
INJECTORS TABLE
");
• refit all parts by following the disassembly instructions in
reverse order and taking care to position the burner cap
correctly on the burner.
12.7.1 Minimum flow of valved cooking hob taps
• Switch on the burner and turn the control knob
towards the minimum flow position ;
• remove the knob;
• using a screwdriver, adjust the internal screw Z
until the correct low flame is obtained;
• refit the knob.
12.7.2 Minimum flow of non-valved cooking hob taps
• Switch on the burner and turn the control knob
towards the minimum flow position ;
• remove the knob;
• insert a small screwdriver into the rod of the tap
and adjust the internal screw Z until the correct
low flame is obtained;
• refit the knob.
• Unscrew the adjustment screw Z to increase the flow, or tighten it to reduce the flow.
• The adjustment is correct when the low flame measures approximately 3 or 4 mm.
• When changing quickly from maximum to minimum flow and vice versa make sure that the
flame does not go out.
GENERAL INJECTORS TABLE
POWER Watt
CONSUMPTION
TYPE OF GAS
Mbar
NOZZLE NO.
BURNERS
POSITION TYPE
MAX.
MIN.
MAX.
115
RAPID
3000
750
286 l/h
97
SEMI RAPID
1750
480
167 l/h
72
AUXILIARY
1000
330
95 l/h
128
TRIPLE-RING
3300
1300
298 l/h
NATURAL GAS
20
94
FISH KETTLE
1900
750
181 l/h
85
RAPID
3000
750
219 g/h
65
SEMI RAPID
1750
480
128 g/h
50
AUXILIARY
1000
330
73 g/h
93
TRIPLE-RING
3300
1300
241 g/h
LPG
BUTANE
PROPANE
30
28
37
68
FISH KETTLE
1900
750
138 g/h
12.8 Connecting
to
LPG
Use a pressure regulator and connect to the cylinder in compliance with the guidelines set out in
standards regulations in force.
Note: L.P.G. cookers MUST NOT be installed below ground level i.e. in a basement or aboard
any
boat, yacht or other vessel.