Rg6-5, Rg6-5 accessories, Description – Extron electronic RG6-5 User Manual
Page 2

18 AWG
(solid)
0.040"
1.02 mm,
Solid Cu
6.6 ohms/
1k ft
22 ohms/
1 km
Bonded Alum.
Foil and
Tinned Cu
Braid (95%)
2.4 ohms/
1k ft,
7.9 ohms/
1 km
53.1
16.2
75
83%
1
5
10
20
50
71
100
135
180
200
270
400
750
1000
3000
-0.3
-0.5
-0.8
-1.0
-1.5
-1.8
-2.1
-2.4
-2.7
-2.9
-3.4
-4.6
-6.5
-7.5
-16.9
-0.8
-1.8
-2.5
-3.3
-5.0
-5.8
-6.8
-7.8
-9.0
-9.5
-11.2
-15.0
-21.2
-24.6
-55.4
22-100-02 (500')
RG6-5
175
5
coax
500 152.4
79.4
0.180 4.57
Single:
0.253 6.43
red, green,
blue, black, yellow
Overall:
0.792 20.12
gray
NEC CM
UL 1581
CSA FT-4
75 °C
Sweep tested 5 MHz to 850 MHz.
Guaranteed return loss: -20 dB max.
min. bend radius 9.0"
Part No. (length)
Model
Description
dB/
100 m
MHz
Nominal
Capacitance
dB/
100 ft
Nominal
Attenuation
Nom.
Vel.
of
Prop.
Shipping
Weights
Standard
Lengths
Conductor
(stranding)
Diameter
Nom. DCR
Shielding
Materials
(% coverage)
Nom. DCR
UL NEC/
C(UL) CEC
UL AWM
Temp.
Nom.
Imp.
(ohms)
No.
of
Cond.
Ft.
m
Nominal
OD
Inch
mm
Nominal
Core OD
Inch mm
pF/ft pF/m
Lbs. kg
(5) 18 AWG Coax • Aluminum Foil (100%) + Tinned Copper Braid Shield
Nonplenum Cable • Gas-injected Foamed Polyethylene Insulation • PVC Inner Jackets • Gray PVC Outer Jacket
www.extron.com
© 2008 Extron Electronics. All rights reserved.
Pricing and specifications may change without notice.
USA West
+1.714.491.1500 / +800.633.9876
+1.714.491.1517 FAX
USA East
+1.919.863.1794 / +800.633.9876
+1.919.863.1797 FAX
China
+86.21.3760.1568 / +400.883.1568
+86.21.3760.1566 FAX
Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Europe
+31.33.453.4040 / +800.3987.6673
+31.33.453.4050 FAX
Dubai
+971.4.2991800
+971.4.2991880 FAX
Asia
+65.6383.4400 / +800.7339.8766
+65.6383.4664 FAX
www.extron.com
© 2008 Extron Electronics. All rights reserved.
Pricing and specifications may change without notice.
USA West
+1.714.491.1500 / +800.633.9876
+1.714.491.1517 FAX
USA East
+1.919.863.1794 / +800.633.9876
+1.919.863.1797 FAX
China
+86.21.3760.1568 / +400.883.1568
+86.21.3760.1566 FAX
Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Europe
+31.33.453.4040 / +800.3987.6673
+31.33.453.4050 FAX
Dubai
+971.4.2991800
+971.4.2991880 FAX
Asia
+65.6383.4400 / +800.7339.8766
+65.6383.4664 FAX
RG6-5
r g 6 s u p e r H I g H r e s o l u t I o n C a B l e s
NOTE: Specifications are subject to change without notice.
RG6-5 Accessories
oPtional aCCessoRies
MoDel DesCRiPtion
Page
PaRt #
Crimp Tools
CTU 300
Universal Crimp Tool
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 738
100-241-02
Hand Wire Stripper
Wire Stripper for 14 to 24 AWG Cables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 739
100-242-01
RG6 Universal Crimp Termination Kit
Crimp Termination Kit with 100 RG6 BNC Male Connectors
. . . . . . . . . . . . . . . . . . . . . .
page 739
100-267-02
Crimp Connectors
BNC Male RG6 Crimp Connectors/50
75 Ohm BNC Male Crimp Connectors for RG6 Cable, Qty. 50
. . . . . . . . . . . . . . . . . . . .
page 741
100-260-01
Compression Tools
CTU 100
Extron Universal Compression Tool
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
page 745
100-181-01
Compression Coax Prep Tool
Coaxial Cable Stripper for MHR, RG59, and RG6 Compression Connectors
. . . . .
page 746
100-183-01
Compression Coax Prep Tool
Replacement Blades
Coaxial Cable Stripper for MHR, M59, RG59, and RG6 Compression Connectors
. . .
page 746
100-184-01
RG6 BNC Compression Kit
Compression Termination Kit with 100 RG6 BNC Male Connectors
. . . . . . . . . . . . . .
page 746
60-538-02
Compression Connectors
BNC Male RG6 Compression Connectors -
Nickel/50
Nickel Plated BNC Male Compression Connectors for RG6 Cable, Qty. 50
. . . . . .
page 748
100-188-01
BNC Male RG6 Compression Connectors -
Gold/50
Gold Plated BNC Male Compression Connectors for RG6 Cable, Qty. 50
. . . . . . . .
page 748
100-188-02
For Bulk Pins, Ferrules, Sleeves and Bodies, see page 743.
722