7 Service Instructions

7.1 General

WARNING — To reduce the risk of electrical shock, do not remove cover or back.
No user-serviceable parts inside. Refer to qualified service personnel.

7.2 Status

LEDs

The status LEDs on the front of the KDD-PSU shows the state of the external and
internal voltages and the operating state of the internal fans:

AC

On = AC Power OK

Ext.Batt

On = External battery voltage is OK

Fans

On = Both internal fans are OK

Off = One or both internal fans don’t run

48V-1

On = 48 V DC output 1 is OK

48V-2

On = 48 V DC output 2 is OK

12V

On = 12V DC power supply for external Hub is OK (for future use)

7V

On = 7V DC power for RAM Recorder buffering is OK


7.3 Fuses


Double pole neutral fusing — Disconnect mains power prior to servicing.

Use correct fuse — Use only the fuse type and rating specified for this product.

7.3.1 Main

Fuses

Fuse type: 2x T 8A / H 250V

Manufacturer: WICKMANN 181, SCHURTER SPT 0001.2513
Order no.: 003 117 300 214

7.3.2 Internal Fuses on Board RY3781


T1, T2 F 7A / 250 V

Manufacturer: LITTLEFUSE 312007 or SCHURTER FSF 0034.5143
Order no.: 003 117 301 010