beautypg.com

Technical specification, Power supply, Environmental data – Grass Valley KDD-PSU User Manual

Page 17: Mechanical data, 4 technical specification, 1 power supply, 2 environmental data, 3 mechanical data

background image

KDD-PSU Power Supply Unit

4 Technical

Specification

4.1 Power

Supply


Line voltage

100V-240V AC +/-10%,

power factor corrected

Line frequency

50/60Hz +/- 5%


Power consumption

max. 375W


Leakage current

< 2 mA at 250V AC


DC-OUT

2x 48V DC, total 6A max


EXT BATT IN

12V … 24V, 0.5A


RAM Recorder
buffer voltage:

7V DC, max 300mA. (Only with ext. battery input or AC In)

4.2 Environmental

Data

Storage temperature

-20

°C to +70°C (-4°F to 158°F)


Operating temperature

+5

°C to +40°C (41°F to 104°F)


Relative humidity

≤ 95% non-condensing


Electromagnetic
environment

E2 (according to EN55103-1, -2)

4.3 Mechanical

Data

Height 1RU

44 mm

(1.73 inch)

Width

482 mm

(19 inch)

Depth

240 mm

(9.45 inch)

Weight

2.8 kg

(6.2 lb)

Instruction Manual