Grass Valley K2 Media Client Field Kit Upgrade Instruction Manual Nov.18 2008 User Manual
Page 10

10
K2 Media Client Field Kit Upgrade Instructions
July 22, 2008
K2 Media Client Field Kit Upgrade Instructions
CAUTION: To avoid possible damage to circuit boards and other
sensitive parts, turn off the K2 Media Client and disconnect AC power
before opening the top cover or removing any internal parts.
7. Remove the top cover from the K2 Media Client
8. Remove the existing SD Codec board.
9. Switch the positions of the RTP card and Dual port network card.
10. Install the HD codec board. If you are also adding mezzanine boards, refer to
instructions earlier in this document as appropriate.
11. Replace the top cover.
12. Connect power cables.
13. Start up the K2 Media Client.
14. Follow the procedure in the K2 Media Client Service Manual to make motherboard
CMOS settings, which involves the following steps:
• During startup processes, access BIOS settings.
• Make BIOS settings.
• Save settings and restart the K2 Media Client.
15. At startup, ignore “Found New Hardware” messages.
16. Install K2 client software and configure based on customer requirements.
!