K2 Dyno Replay System Quick Start Guide
7
Cable K2 Summit Client
Cable K2 Summit Client
If desired, mount the K2 Summit Client in an equipment rack. Refer to the K2 System
Guide for rack mount procedures.
Make K2 Summit Client cable connections as illustrated.
Each channel can be both an input (record channel) and an output (play channel). For
the K2 Dyno Replay System documented in this Quick Start Guide, C1 and C2 are
record channels and C3 and C4 are play channels.
For complete cabling instructions, refer to the K2 System Guide. If using ChannelFlex
Suite™ features, refer to the K2 Dyno Controller Installation Manual and the K2
AppCenter User Manual.
Cable K2 Dyno Controller
Make K2 Dyno Controller cable connections as illustrated.
The Ethernet connection between the K2 Summit Client and the K2 Dyno Controller
can be via direct connect cable or via an Ethernet switch.
Power
cord
Power
cord
AES
audio
Keyboard
and mouse
VGA
monitor
Channels (C1, C2, C3, C4) are bi-directional
Ethernet
(Control port)
Use C1 as record
channel. Connect
Use C2 as record
channel. Connect
Use C3 as
play channel.
Use C4 as
play channel.
100-240 V~
4A 50-60Hz
RS-232
Power
cord
Keyboard
and mouse
VGA
monitor
Ethernet (Control port)
GB1