GUIDE TO INSTALLATION AND OPERATION
6 | FOL-1601
• Use the keys on the local control panel to step through the displayed menu to configure and adjust
the FOL-1601.
FOL-1601 MENU
STATUS
STATUS
OK
NO OPTICAL INPUT
(< -14 dBm)
NO RF OUTPUT
OPTICAL OVERLOAD
(> 0 dBm)
OPT SIG STRENGTH [-14 dBm, -13 dBm, -12 dBm,….., -1 dBm, 0 dBm] (read-only)
RF SIG STRENGTH
[-41 dBm, -40 dBm, -39 dBm,….., -1 dBm, 0 dBm] (read-only)
RF OUT GAIN
[-31 dB, -30 dB, -29 dB,….., -1 dB, 0dB]
USER PRESET
LOAD
[USER 1, USER 2, USER 3, USER 4, USER 5]
SAVE
[USER 1, USER 2, USER 3, USER 4, USER 5]
CONFIG ALARMS
NO OPTICAL INPUT
ALARM LEVEL
[GREEN, YELLOW, RED, FLASH RED]
ALARM
REPORT
[NONE, GPI]
NO RF OUTPUT
ALARM LEVEL
[GREEN, YELLOW, RED, FLASH RED]
ALARM
REPORT
[NONE, GPI]
OPTICAL OVERLOAD
ALARM LEVEL
[GREEN, YELLOW, RED, FLASH RED]
ALARM
REPORT
[NONE, GPI]
VERSION
FOL-1601:xxx
FACTORY
DEFAULT
[RESTORE]
Notes on the menu items:
RF OUT GAIN – adjust for the correct output level to compensate for optical loss after system installation.
USER PRESET – the FOL-1601 has 5 registers that can store full configuration data. Use the LOAD and
SAVE menu items to select a register (USER 1 to USER 5) and either save the current configuration into that
register (SAVE) or reconfigure the FOL-1601 according to the contents of the register (LOAD).
CONFIG ALARMS / ALARM LEVEL – for each alarm, set the color that will be displayed on the FOL-1601’s
status LED.
CONFIG ALARMS/ ALARM REPORT – for each alarm, select whether that alarm will be reported on the
Densité frame’s GPI output. See the manual for the frame’s controller card for more information about this
feature.
FACTORY DEFAULT – restore settings to factory-default values (shown underlined in the parameter value
lists above)