GUIDE TO INSTALLATION AND OPERATION

6 | FOL-1601

• Use the keys on the local control panel to step through the displayed menu to configure and adjust

the FOL-1601.

FOL-1601 MENU

STATUS

STATUS

OK

NO OPTICAL INPUT

(< -14 dBm)

NO RF OUTPUT

OPTICAL OVERLOAD

(> 0 dBm)


OPT SIG STRENGTH [-14 dBm, -13 dBm, -12 dBm,….., -1 dBm, 0 dBm] (read-only)



RF SIG STRENGTH

[-41 dBm, -40 dBm, -39 dBm,….., -1 dBm, 0 dBm] (read-only)



RF OUT GAIN

[-31 dB, -30 dB, -29 dB,….., -1 dB, 0dB]



USER PRESET

LOAD

[USER 1, USER 2, USER 3, USER 4, USER 5]


SAVE

[USER 1, USER 2, USER 3, USER 4, USER 5]



CONFIG ALARMS

NO OPTICAL INPUT

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]


ALARM

REPORT

[NONE, GPI]


NO RF OUTPUT

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]


ALARM

REPORT

[NONE, GPI]


OPTICAL OVERLOAD

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]


ALARM

REPORT

[NONE, GPI]

VERSION

FOL-1601:xxx


FACTORY

DEFAULT

[RESTORE]


Notes on the menu items:

RF OUT GAIN – adjust for the correct output level to compensate for optical loss after system installation.

USER PRESET – the FOL-1601 has 5 registers that can store full configuration data. Use the LOAD and
SAVE menu items to select a register (USER 1 to USER 5) and either save the current configuration into that
register (SAVE) or reconfigure the FOL-1601 according to the contents of the register (LOAD).

CONFIG ALARMS / ALARM LEVEL – for each alarm, set the color that will be displayed on the FOL-1601’s
status LED.

CONFIG ALARMS/ ALARM REPORT – for each alarm, select whether that alarm will be reported on the
Densité frame’s GPI output. See the manual for the frame’s controller card for more information about this
feature.

FACTORY DEFAULT – restore settings to factory-default values (shown underlined in the parameter value
lists above)