beautypg.com

EverFocus EAN900 User Manual

Page 20

background image

EAN900

20

Authentication: Check the box, if the SMTP server requires Authentication (user/
password).

User name: Input the login user ID if the SMTP server requires Authentication.

Password: Input the password if the SMTP server requires authentication.

Receiver Address: Input the e-mail address for receiving e-mail message when the
EVENT is enabled and triggered. Please use “;” to separate address.

Sender Address: Input sender’s e-mail address, so that receiver can recognize the
sender when an event message is sent out.

Send Test Mail: Press

button to send a testing mail to the assigned

address.


Set FTP

The settings relating to the FTP server used to transmit the alarm images can be

configured.

FTP Server: Enter the IP address or the host name of the FTP server.
FTP Port: Enter the port number for FTP server. Default is 21.
Recording Path: Assign the recording path.
User Name: Set FTP User’s name.

Password: Set FTP password.
PASV mode: Check to enable Passive mode, normally enable Passive mode. When
failed to establish the connection, uncheck "PASV" mode.
Test FTP Server: Press

button to send a testing file to the assigned

FTP server.

Press Apply to apply the setting changes or Reset to reset without saving the
change.