Service, Troubleshooting – Grass Valley 2020DAC D-To-A User Manual
Page 25
2020DAC Instruction Manual
19
Service
Service
The 2020DAC modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field.
Troubleshooting
If your module is not operating correctly, proceed as follows:
■
Check frame and module power. If power is not present, check the fuse
on the +24 V input to the module as illustrated in
.
■
Check for presence and quality of input signals.
■
Verify that source equipment is operating correctly.
■
Check cable connections.
Figure 12. Location of Module Fuse
for the location of PWR LED and
for proper LED indications.
If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.
Refer to the
at the front of this document for
the Grass Valley Customer Support Information number. Check the Grass
Valley Group web site at http://www.grassvalleygroup.com for further
information on modular products.
8023_08
F1
Fuse: 2 A FAST, 125 V