Problem
Possible Cause
Possible Solution
Air pump does
not start
Power is off
Turn power on
Power failure
Check power supply or
contact local power company
Voltage drop/
Overload
Check/Replace the GFI (Ground
Fault Interrupter)
Power cord is not
connected
Connect power cord
Air pump stops
after starting
Air pump is
overheating
Allow pump to cool
Power/Current
overload
Check length/size of power cable.
Check or replace GFI
Diminished
air flow rate or
no air flow
Kink/damaged tubing
Repair/replace tubing
Dirty filter media
Clean filter media
Worn/damaged
diaphragm
Consult your dealer. Replace
diaphragm and flappers
Air line is submerged
below operating depth
Raise air line to desired depth
7
Troubleshooting Guide
Always turn off power before inspecting the pump. Failure to observe this precaution can
result in a serious accident.
Before ordering repairs, carefully read through this instruction booklet. If the problem per-
sists, contact your dealer.