Northfire 42
11
INSTALLATION INSTRUCTIONS
Cont...
MO
SPEED
CONTROL
110F (43ºC) N.O.
THERMAL SNAP
SWITCH
CONVECTION BLOWER
LINE
GROUND
NEUTRAL
SIDE OF GAS
FIREPLACE
120 VAC
white
black
SPEED CONTROL
LINE
GROUND
NEUTRAL
110F (43ºC) N.O. THERMAL
SNAP SWITCH
CONVECTION BLOWER
VENT TERMINATION
1. See ALLOWABLE TERMINATION LOCATIONS and establish a suitable vent termination
location.
2. In heavy snowfall areas make sure vent termination is located where it cannot be blocked by
snow or snow from snow removal equipment.
3. Locate vent termination away from plants, bushes or any other object near the vent
termination that will interfere or obstruct the air flow around it.
4. DO NOT recess vent termination into walls, sidings or planters.
5. Vent terminations located below 7ft from grade level or anywhere that it can be a burn hazard
to the public, such as patios and balconies, must be protected with an Archgard approved
termination cage.
WIRING DIAGRAM
ALLOWABLE FIREPLACE LOCATIONS
See venting chart for
maximum and minimum
vertical/horizontal
venting configurations.