ARAG BRAVO 300S - Multi-row crop sprayers, Direct connection / RCU Installation - Software ver User Manual
Page 16

16
• Connect the connector marked with "DD" to the pilot valve, and then the other connectors, as
specified on the table:
Control
Movement
Connector
Section movement / AUX switch opening
1 - 2 - 3 - 4 - 5 - 6
Opening
1 ÷ 6 A
Closing
1 ÷ 6 C
Boom height
Opening
AA
Closing
AC
Boom locking
Opening
BA
Closing
BC
Boom levelling
Opening
CA
Closing
CC
Tab. 3
8.5
Connection of sensors and other available functions
Fix the connectors to the relevant functions according to the initials indicated in your assembly
general diagram (Par. 6.1).
Harness cables are marked with a symbol denoting their functions: please see the
table for correct harness instructions.
Use ARAG sensors: use of unsuitable sensors not provided by ARAG automatically
voids the warranty.
ARAG is not liable for damages to the equipment, persons, animals or things caused
by failure to observe the above instructions.
DIRECT CONNECTION HARNESS
Item
Main connection
Alternative connection
f
Flowmeter
-
g
Main valve
-
M
Pressure sensor
-
p
Control valve
-
r
Foam marker
-
s
Speed sensor
-
t
Filling flowmeter
RPM Sensor or Pump Protector
X
Level sensor
-
Tab. 4