5 maintenance / diagnostics / repairs, 1 troubleshooting, 6 technical data – ARAG Skipper LT - Satellite Navigator User Manual
Page 12: 7 disposal at the end of service, 6 technical data 7 disposal at the end of service, 5maintenance / diagnostics / repairs, 6technical data, 7disposal at the end of service
![background image](https://www.manualsdir.com/files/811987/content/doc012.png)
12
5
Maintenance / diagnostics / rePairs
- Clean only with a soft wet cloth.
- DO NOT use detergents or aggressive products.
- DO NOT aim water jets directly at the navigator.
5.1 Troubleshooting
ProBleM
cause
solution
The display does not switch on
No power supply
• Check power supply connection.
No signal enabling treatment to
SKIPPER LT
Power cable improperly
connected
• Check green lead connection to power
cable
(par. 4.7).
Improper set-up
• Check set-up
(par. 4.7).
Display shows message
The GPS receiver doesn't give
valid data
Wrong GPS antenna cable con-
nection
• Check connection with GPS antenna
(par. 4.7).
Satellite connection in progress
• Wait for connection to be established.
Display shows message
Differential correction not
available
DGPS signal not available in the
work area
• Disable DGPS.
DGPS connection in progress
• Wait for connection to be established.
Tab. 1
6
technical data
Description
SKIPPER LT
Display
LCD 4", 65000 colors, 420 cd/m
2
Power supply
9 - 15 Vdc
Working temperature
0 °C ÷ 45 °C
+32 °F ÷ +113 °F
Storage temperature
-20 °C ÷ 60 °C
-4 °F ÷ +140 °F
Weight
550 g
1 USB 1.1 port
HOST
Treatment input
Active high (+12 Vdc)
Tab. 2
7
disPosal at the end of service
Dispose of the system in compliance with the established legislation in the country of use.