2. While holding the molded hose steady just below the Trim Grip™ (Figure

3a), grasp and turn the Trim grip™ 1/4 turn counterclockwise (figure 3b).

Next, pull down on the molded hose to disengage the lower assembly

(figure 3c).

3. remove the port plug from a medium pres-

sure (MP) port on the regulator using an ap-

propriately sized wrench (Figure 4).

4. check to ensure the hose o-ring is present

and in good condition, tighten the threaded

end of the hose into the port. Torque to 40

inch-pounds (4.5 nm) with a 9/16" wrench

(figure 5).

5. Secure buoyancy compensator to cylinder and attach first stage regulator

to cylinder valve.

6. check to ensure the connection o-ring on the lower assembly is present

and in good condition.

Figure 4

Figure 5

Figure 3b

Figure 3a

Figure 3c