For UK use only

For Europe use only

Instructions for the Installer

The oven is designed to be connected to
230 V (50 Hz) electricity supply.
The oven has an easily accessible terminal
block which is marked as follows:
Letter L

-

Live terminal

Letter N

-

Neutral terminal

or E

-

Earth terminal

THIS OVEN MUST BE
EARTHED.

The cable used to connect the oven to
the electrical supply must comply to the
specifications given below.

It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a minimum
gap of 3mm between the switch contacts
and of a type suitable for the required load
in compliance with the current rules.
The switch must not break the yellow and
green earth cable at any point.
the yellow and green earth cable should
be 2-3 cm longer than the other cables.
Important
After installation and connecting, the cable
must be placed so that it cannot at any
point reach a temperature of more than
60°C above the ambient temperature.
Before the oven is connected, check that
the main fuse and the domestic installation
can support the load and that the power
supply is properly earthed.

The manufacturer declines any
responsibility should these safety
measures not be carried out.

Connection

Min. size

Cable / flex Fuse

via

Cable/flex type

13 A socket

2.5 mm

2

3 core

13 A min.

outlet

butyl

13 A spur box

insulated

Oven

2.5 mm

2

PVC/PVC

15 A min.

Control

twin and

Circuit

earth

20 A max.

Min. size Cable/ Cable / flex type Fuse
flex

1.5 mm

2

H07 RN-F, H05 RN-F, 13 A
H05 RR-F, H05 VV-F,
H05 V2V2-F (T90),
H05 BB-F