ENGINE/GENERATOR
ISUZU 3CE1 Diesel Engine
Starting:
12V Electric 8D Battery
Oil sump capacity:
6.7 qts (6.3 L)
Low Oil Pressure Shutdown: Solenoid actuated fuel
rack instant shutdown
Generator: 8kW , 60 Hz, 1-ph, 1800 rpm
CAT C1.5 Diesel Engine
Starting:
12V Electric 8D Battery
Oil sump capacity:
5.9 qts (5.6 L)
Low Oil Pressure Shutdown: Solenoid actuated fuel
rack instant shutdown
Generator: 8kW , 60 Hz, 1-ph, 1800 rpm
DIMENSIONS
Height:
6’
Length:
16’
Width:
6’ 8”
SPECIFICATIONS AND SERIAL NUMBERING LOCATION
HEATERS
Two (2) I.C.E. Frost Fighter IDF 500
325,000 BTU Output with 2.5 gph, 60° solid nozzle
WEIGHT
Empty:
3,500 lbs.
With Fuel:
4,651 lbs.
Each standard heater includes one (1) 16 in.
heated air outlet, which connects easily to the
ducting. Limit to 110feet of 16” ducting.
Heated Air Output: 2,850 CFM per heater w/o duct.
Temperature Rise:185
°
with duct creating
0.5 in. static pressure
Operating Time: More than 24 hours without refuel-
SERIAL NUMBER LOCATIONS
TRAILER: Plate attached to right rear corner of
frame
ISUZU ENGINE: Plate attached to top of valve
cover
CAT ENGINE: Plate attached to injector pump on
right side of engine
FUEL SYSTEM
Fuel Requirements: No.1 fuel oil
Fuel Capacity: 191.1 Gallons
Fuel Consumption:
Engine: ISUZU 3CD1 0.5 gal/hour (1.9L/
hr)
Engine: CAT C1.5 0.5 gal/hour (1.9L/hr)
6. Check igniter tips for correct location for the unit you are setting up. Adjust if necessary. (see owners
manual)
For the IDF 500:
·
5/32 apart
·
¼” above center of nozzle
·
1/8” in front of nozzle
7. Re-install the fuel rail, hook up fuel lines etc.
8. Restart the heater and check the flue gas for smoke using the True-Spot Smoke Tester.
9. If you get a smoke test reading in the 2 to 3 range you will be ready to fine tune the burner to
achieve a #1 or possibly a 0 on the smoke scale. If you still have heavy smoke, you may have to go
down another nozzle size to be able to get the burner to burn efficiently.
Fine Tuning the Frost Fighter Burners
1. Use the True-Spot Smoke Tester to determine where you are on the Smoke Scale.
2. To reduce the amount of smoke, open the band 1 or 2 numbers and recheck with the True-Spot
Smoke Tester.
3. Make further adjustments if necessary to achieve the lowest number you can on the Smoke Scale.
4. Tighten the air band and shutter-securing screws to prevent them from moving after you have made
the adjustments.
MAXI-HEAT
®
SETUP PROCEDURE