H

EAT

8

Notes:

1. Blow thru heaters can have a maximum of two stages.

2. VFD controllers cannot be supplied with blow thru heaters.

3. Specific kW ratings are available within the ranges shown. Refer to selection program.
4. Heaters above 480v must utilize one time secondary limits only.

Notes:

1. Draw thru heaters can have a maximum of four stages.

2. All heaters that have an AMP draw greater than 48 AMPs will have a minimum of two stages.

3. Specific kW ratings are available within the ranges shown. Refer to selection program.
4. Heaters above 480v must utilize one time secondary limits only.

Min Max

Min Max

Min Max

Min Max

Min Max

Min Max

Min

Max

Min

Max

Min

Max

kW

3

5

3

5

4

5

AMPs 26.1 43.5 26.1 43.5 34.8 43.5

kW

3

10

3

10

4

10

6.0

16

7

16

9

20

AMPs 14.4 48.1 14.4 48.1 19.2 48.1 28.8 76.9 33.7 76.9 43.3 96.2

kW

3

11

3

11

4

11

6.0

18

7

18

9

22

AMPs 13.0 47.8 13.0 47.8 17.4 47.8 26.1 78.3 30.4 78.3 39.1 95.7

kW

3

13

3

13

4

13

6.0

22

7

22

9

26

AMPs 10.8 46.9 10.8 46.9 14.4 46.9 21.7 79.4 25.3 79.4 32.5 93.9

kW

3

13

3

20

4

26

4.0

26

7

28

9

34

12

46

14

46

16

46

AMPs 8.3 36.1 8.3 55.5 11.1 72.2 11.1 72.2 19.4 77.7 25.0 94.4 33.3 127.7 38.9 127.7 44.4 127.7

kW

3

13

3

20

4

26

4.0

26

7

32

9

34

12

49

14

49

16

49

AMPs 7.5 32.6 7.5 50.2 10.0 65.3 10.0 65.3 17.6 80.3 22.6 85.3 30.1 123.0 35.1 123.0 40.2 123.0

kW

3

13

3

20

4

26

4.0

26

7

52

9

64

12

76

14

88

16

96

AMPs 3.8 16.3 3.8 25.1 5.0 32.6 5.0 32.6 8.8 65.3 11.3 80.3 15.1 95.4 17.6 110.4 20.1 120.5

kW

3

13

3

20

4

26

4.0

26

7

52

9

64

12

76

14

88

16

96

AMPs 3.0 13.1 3.0 20.1 4.0 26.1 4.0 26.1 7.0 52.2 9.0 64.3 12.0 76.3 14.1 88.4 16.1 96.4

UNIT

VOLTAGE

AND PHASE

DRAW-THRU ELECTRIC HEAT

Unit Size

02

03

04

06

08

10

12

14

17

Single Phase

115

230

208

277

Three Phase

208

230

460

575

Min Max

Min Max

Min Max

Min Max

Min Max

Min Max

Min

Max

Min

Max

Min

Max

kW

3

5

3

5

4

5

AMPs 26.1 43.5 26.1 43.5 34.8 43.5

kW

3

9

3

9

4

9

6

9

7

9

AMPs 14.4 43.3 14.4 43.3 19.2 43.3 28.8 43.3 33.7 43.3

kW

3

11

3

11

4

11

6.0

11

7

11

9

11

AMPs 13.0 47.8 13.0 47.8 17.4 47.8 26.1 47.8 30.4 47.8 39.1 47.8

kW

3

13

3

13

4

13

6.0

13

7

13

9

13

AMPs 10.8 46.9 10.8 46.9 14.4 46.9 21.7 46.9 25.3 46.9 32.5 46.9

kW

3

13

3

16

4

16

4.0

16

7

16

9

16

12

16

14

16

AMPs 8.3 36.1 8.3 44.4 11.1 44.4 11.1 44.4 19.4 44.4 25.0 44.4 33.3 44.4 38.9 44.4

kW

3

13

3

18

4

18

4.0

18

7

18

9

18

12

18

14

18

16

18

AMPs 7.5 32.6 7.5 45.2 10.0 45.2 10.0 45.2 17.6 45.2 22.6 45.2 30.1 45.2 35.1 45.2 40.2 45.2

kW

3

13

3

20

4

26

4.0

26

7

38

9

38

12

38

14

38

16

38

AMPs 3.8 16.3 3.8 25.1 5.0 32.6 5.0 32.6 8.8 47.7 11.3 47.7 15.1 47.7 17.6 47.7 20.1 47.7

kW

3

13

3

20

4

26

4.0

26

7

46

9

46

12

46

14

46

16

46

AMPs 3.0 13.1 3.0 20.1 4.0 26.1 4.0 26.1 7.0 46.2 9.0 46.2 12.0 46.2 14.1 46.2 16.1 46.2

06

08

UNIT

VOLTAGE

AND PHASE

Three Phase

208

230

460

575

BLOW-THRU ELECTRIC HEAT

Unit Size

14

17

10

12

04

Single Phase

02

03

208

230

277

115

ENVIRO-TEC