beautypg.com

Kcm-5211 hardware manual – ACTi KCM-5211 User Manual

Page 8

background image

www.acti.com


KCM-5211 Hardware Manual

8

2) Serial Port

This port connects to serial devices via RS-485 or RS-422 protocols. Use the supplied serial

port terminal block to connect the wires from the camera to the serial device.

See

Serial Port Connection

on page 11 for connection details.

3) Ethernet Port

The IP device connects to the Ethernet via a standard RJ45 connector. Supporting NWAY, this

IP device can auto detect the speed of local network segment (10Base-T/100Base-TX

Ethernet).

4) Reset Button

Step 1:

Switch off IP device by disconnecting the power cable

Step 2:

Press and continue to hold the Reset Button (with a sharp tipped object, like a pen.)

Step 3:

Reconnect the power cable while continuing to hold the reset button.

The red

Power LED light will flash on for 3 second first, turn off for about 15 seconds, flash on for

another second and turn off again. By this time the reset to default operation is already

completed.

This will take around 20 seconds from power up.

You may then release the

reset button. This length of time fluctuates slightly with the environment. The Power LED light

will come back on and stay on after a few more seconds. The unit will start up with factory

default settings automatically.

1

2

3

FUSE 1A



NPN

DC TO DC

DI

DO

3.3V



DC POWER

GND

1

2

3

4

CONVERTER

EARTH GND

DO

DI

RELAY

SW

DIODE

DEVICE

-

+

POWER INPUT

CAMERA