6641-2252

Type tests and environmental conditions

Environmental phenomena Basic standard Description

Test levels

ESD

EN 61000-4-2

Enclosure

Contact: ±6 kV Air: ±8 kV

Fast transients

EN 61000-4-4

Power port

±4 kV

Ethernet ports

±2 kV

Earth port

±1 kV

Surge

EN 61000-4-5

Power port

L-E: ±0.5 kV, 12 Ω, 9 μF, 1.2/50 μs
L-L: ±0.5 kV, 2Ω, 18 μF, 1.2/50 μs
L-E: ±2 kV, 42 Ω, 0.5 μF, 1.2/50 μs
L-L: ±2 kV, 42Ω, 0.5 μF, 1.2/50 μs
L-E: ±8.4 kV, 100 Ω, 0.05/0.1 μs
L-L: ±8.4 kV, 100 Ω, 0.05/0.1 μs

Ethernet ports

L-E: ±2 kV, 2 Ω

Power frequency magnetic field EN 61000-4-8

Enclosure

300 A/m; 0, 16.7, 50, 60 Hz

Pulsed magnetic field

EN 61000-4-9

Enclosure

300 A/m

Radiated RF immunity

EN 61000-4-3

Enclosure

20 V/m @ (80 MHz – 2.7 GHz)
10 V/m @ (2.7 Ghz – 6 GHz)*
1 kHz sine, 80% AM

Conducted RF immunity

EN 61000-4-6

Power port

10 V, 80% AM, 1 kHz; (0.15 – 80) MHz

Ethernet ports

10 V, 80% AM, 1 kHz; (0.15 – 80) MHz

Earth port

10 V, 80% AM, 1 kHz; (0.15 – 80) MHz

Radiated RF emission

CISPR 16-2-3

Enclosure

Class A

ANSI C63.4
(FCC Part 15)

Class A

Conducted RF emission

CISPR 16-2-1

Power port

Class A

Ethernet ports

Class B

Dielectric strength

EN 60950-1

Power port to all
other ports

1.5 kV ACrms, 50 Hz, 1 min

Fast Ethernet ports to
all other ports (not
between PoE ports)

1.5 kV ACrms, 50 Hz, 1 min

Gigabit Ethernet ports
to all other ports

500 V ACrms, 50 Hz, 1 min

Environmental

Temperatures

Operating

–40 to +70°C (–40 to +158°F)**

Storage and transport

–50 to +85°C (–58 to +185°F)

Humidity

Operating

5 to 95 % relative humidity

Storage and transport

5 to 95 % relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

15 years @ 25°C (+77°F)

MTBF

Viper-x12-P8:
448 000 h

MIL-C217F2, GB, 25°C (+77°F)

Viper-x12-P8-T3G:
403 000 h

Vibration

IEC 60068-64
(random)

Operating

5 – 20 Hz, 0.0405 g²/Hz
20 – 150 Hz, –6 dB / oct 5h, 1.14 grms

Shock

IEC 60068-2-27 Operating

10 g, 30 ms, 20 g, 11 ms, 100 g, 6 ms

Enclosure

EN 60950-1

Zinc (front)
Aluminum (rear)

Fire enclosure

Dimension W x H x D
With connectors

See "Dimensions" chapter for details

Weight

1.7 kg

Degree of protection

EN 60529

Enclosure

IP67***

Cooling

Convection

* Only Viper-x12-P8 according to EN50121-3: 2015
** Refer to “Safety” section
*** Provided all connectors are connected with IP67 cabling or fitted with protective caps (delivered with the unit),
tightened to the specified torque