4 environmental specification, 1 climatic, 2 mechanical – Westermo U200 Operator manal User Manual
Page 47: 3 electromagnetic compatibility (emc), 4 radiated immunity, 5 conducted immunity

V4.5
www.westermo.com
U/R/T200 series
- 47 -
13.4 Environmental Specification
Indoor use or corresponding environment
Altitude up to 2000M
Operating temperature (-40 .. +65’C) (55deg on F8)
Humidity 5-95’C
Enclosure IP40
13.4.1 Climatic
Cold
IEC 68-2-1 Ad (-40 ‘C operational 16 Hours)
Storage
IEC 68-2-1 Ad (-40 ’C 16 Hours)
Dry Heat
IEC 68-2-2 Bd (+70 ’C operational 16 Hours)
Humidity
IEC 68-2-30 Db (25 ‘C .. 55 ‘C 95% 6 Cycles 24 Hours)
13.4.2 Mechanical
Oscillation
IEC 255-21-1 Class 1
Shock
IEC 255-21-2 Class 1
Enclosures
IEC 529, IP 40
13.4.3
Electromagnetic Compatibility (EMC)
Industrial Immunity
EN 61000-6-2
Industrial Emission
EN 50081-2
Home / Office Emission EN 50081-1
13.4.4 Radiated
Immunity
ESD
EN 61000-4-2 (4/8 kV)
Magnetic Field
EN 61000-4-8 (300A/m)
RF Field Disturbance
EN 61000-4-3
10
V/m
80%
AM
80
..
1000MHz
13.4.5 Conducted
Immunity
Fast
Transients
EN
61000-4-4
AC/DC
2kV,
Signal
1kV
Surge
Immunity
EN
61000-4-5
AC: 2kV/1kV
DC:
0.5kV/0.5kV