Westermo RFI-2xx User Manual
Page 15
15
6641-22310
Ethernet TX
Electrical specification
IEEE std 802.3. 2005 Edition
Data rate
10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto
Duplex
Full or half, manual or auto
Circuit type
TNV-1
Transmission range
Up to 150 m with CAT5e cable or better*
Isolation to
All other
Connection
RJ-45 auto MDI/MDI-X
Shielded cable
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails*
Conductive housing
Yes
Number of ports
3
* NOTE! Railway installation close to the rails.
To minimise the risk of interference, a shielded cable is recommended when the cable is located
inside 3 m boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this
port. This earthing point should have a low impedance connection to the conductive enclosure of
the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be
connected to the earthing system of an installation and may be directly connected to the protective
earth. Refer also to "Safety" section.
IO / Relay output
Connect resistance
30 W
Isolation to
All other
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Maximum voltage/current
60 VDC / 80 mA
IO / Digital input
Voltage levels
Vih > 8V Vil < 5V
Iin = 2.9mA @60V
Isolation to
All other
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Maximum voltage
60 VDC
USB
Electrical specification
USB 2.0 host interface
Data rate
High speed 480mbit/s
Circuit type
SELV
Maximum supply current
500 mA
Isolation to
All other except Console
Connection
USB receptacle connector type A
Conductive housing
Yes