Type tests and environmental conditions – Westermo MCW-211 User Manual
Page 9

9
6645-2204
Type tests and environmental conditions
Electromagnetic Compatibility
Phenomena
Test
Description
Level
ESD
EN 61000-4-2
Enclosure contact
± 4 kV
Enclosure air
± 8 kV
RF field AM modulated
IEC 61000-4-3
Enclosure
10 V/m 80% AM (1 kHz), 80 – 2700 MHz
Fast transient
EN 61000-4-4
Signal ports
± 1 kV
Power ports
± 2 kV
Surge
EN 61000-4-5
Signal ports balanced
± 2 kV line to earth, ± 1 kV line to line
Power ports
± 2 kV line to earth, ± 2 kV line to line
RF conducted
EN 61000-4-6
Signal ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Voltage dips
and interruption
EN 61000-4-29
DC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
Radiated emission
EN 55022
Enclosure
Class A
Conducted emission
EN 55022
DC power ports
Class A
Dielectric strength
EN 60950
Signal port to other
isolated ports
1.5 kVrms 50 Hz 1 min
Power port to other
isolated ports
2 kVrms 50 Hz 1 min
Environmental
Temperature
Operating
–25 to +70ºC
Maximum surface
temperature
135°C (temperature class T4)
Storage & Transport
–40 to +70ºC
Humidity
Operating
5 to 95% relative humidity
Storage & Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
Service life
Operating
10 year
Vibration
IEC 60068-2-6
Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
Shock
IEC 60068-2-27
Operating
15 g, 11 ms
Packaging
Enclosure, MCW-211
UL 94
PC / ABS
Flammability class V-1
Enclosure, MCW-211 Ex
Cabelec 6141
Dimension W x H x D
35 x 121 x 119 mm
Weight
0.25 kg
Degree of protection
IEC 529
Enclosure
IP 21
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail