beautypg.com

Connections ld-63h – Westermo LD-63H AC User Manual

Page 4

background image

4

6072-2281

Connections LD-63H

Power connection
LD-63H DC
(2-position screw-terminal)

Terminal connection (DCE)
(RS-232-C/V.24, 9-position screw-terminal)

Direction

Screw

CCITT V.24

Description

no.

Description

I

8

103

TD/Transmitted Data

O

7

104

RD/Received Data

I

6

105

RTS/Request to send

O

5

106

CTS/Clear to send

1 & 9

102

SG/Signal Ground

I = Input

O = Output on LD-63H

Connection

Power

no.

supply

1

– Voltage

2

+ Voltage

Power connection
LD-63H AC
(3-position screw-terminal)

Connection

Power

no.

supply

L

115**/230V

N

AC power

PE/ Protective Earth

** LD-63H 115V

1

2

3

4

5

L

N

LD-63

RS-422/485

POWER

R+

Rx1

Rx2

Tx1

Tx2

R- T+

T-

TD RD

PWR

LEDs for indication on LD-63H

• PWR: Indicates that the converter has power.
• TD: Indicates that the converter is receiving data on RS-232/V.24 side.
• RD:

Indicates that the converter is sending data on RS-232/V.24 side.

• Rx1: Indicates received data on fiber channel 1.
• Rx2: Indicates received data on fiber channel 2.
• Tx1: Indicates that the converter is sending data on fiber channel 1 from RS-232/V.24 side.
• Tx2: Indicates that the converter is sending data on fiber channel 2 from RS-232/V.24 side.