beautypg.com

Westermo DDW-142-EX User Manual

Page 16

background image

16

6642-22521

Ethernet TX
Electrical specification

IEEE std 802.3. 2005 Edition

Data rate

10 Mbit/s, 100 Mbit/s, manual or auto

Duplex

Full or half, manual or auto

Circuit type

TNV-1

Transmission range

Up to 150 m, with CAT5e cable or better

Isolation to

All other

Connection

RJ-45, auto MDI/MDIX

Shielded cable

Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails.*

Conductive housing

Yes

Number of ports

2

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m

boundary to the rails and connected to this port.

The cable shield should be properly connected (360°) to an earthing point within 1 m from this port.

This earthing point should have a low impedance connection to the conductive enclosure of the apparatus

cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing

system of an installation and may be directly connected to the protective earth.

Console
Electrical specification

LVTTL/LVCMOS-level

Data rate

115.2 kbit/s

Data format

8 data bits, none parity, 1 stop bit, no flow control

Circuit type

SELV

Connection

2.5 mm jack, use Westermo cable 1211-2027

USB
Electrical specification

USB 2.0 host interface

Data rate

Up to 12 Mbit/s (full-speed mode)

Circuit type

SELV

Maximum supply current

500 mA

Connection

USB receptacle connector type A