Westermo DDW-142-EX User Manual
Page 13
13
6642-22521
Electromagnetic Compatibility
Environmental
phenomena
Basic
standard
Description
Test levels
Dielectric strength
EN 60950-1
Power port to other
isolated ports
2000 Vrms 50 Hz 1 min
Ethernet ports to all
other isolated ports
1500 Vrms 50 Hz 1 min
RS-232 port to all
other isolated ports
SHDSL ports to all
other isolated ports
Status out / Digital
in port to all other
isolated ports
Environmental
Temperature
EN 60068-2-1
EN 60068-2-2
Operating
–40 to +70ºC (–40 to +158ºF)
Storage & Transport
–40 to +85ºC (–40 to +185ºF)
Humidity
EN 60068-2-27
Operating
5 to 95% relative humidity
Storage & Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
Service life
Operating
10 years
Reliability prediction
(MTBF)
Operating
437,000 hours (MIL-HDBK- 217F2, GB, 25°C)
Vibration
IEC 60068-2-64
(random)
Operating
5 – 20 Hz: 2 m²/s³
20 – 500 Hz: – 3 dB/oct
3 axis = 3 * 30 min
Shock
IEC 60068-2-27
Operating
6 ms 1000 m/s²
6 directions, 3 shocks/direction
Bump
IEC 60068-2-27
Operating
11 ms 100 m/s²
6 directions, 100 shocks/direction
Packing
Enclosure material
EN 60950-1
Zinc (fire enclosure)
Dimension W x H x D
Without connectors
52.5 x 100 x 92 mm
With connectors
52.5 x 100 x 111 mm
Weight
0.8 kg
Degree of protection
EN 60529
Enclosure
IP 40
Cooling
Convection
Mounting
Enclosure
Horizontal on 35 mm DIN-rail