Type tests and environmental conditions – Westermo MR-2x0 User Manual
Page 10
10
6622-2221 • -29000447
Type tests and environmental conditions
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure contact
± 4 kV
Enclosure air
± 8 kV
RF field AM modulated
EN 61000-4-3
Enclosure
3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1
400 MHz – 2 000
Fast transient
EN 61000-4-4
Signal ports
± 0.5 kV
Power ports
± 1 kV
Surge
EN 61000-4-5
Telecom/Signal ports ± 0.5 kV line to earth
Power ports
± 2 kV line to earth, ± 2 kV line to line
RF conducted
EN 61000-4-6
Power ports
3V/m 80% AM (1 kHz), 0.15 – 80 MHz
Voltage dips and
interruption
EN 61000-4-11
AC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
Radiated emission
EN 55022
Enclosure
Class B
FCC part 15
Class B
Conducted emission
EN 55022
AC power ports
Class A
FCC part 15
AC power ports
Class B
EN 55022
DC power ports
Class B
Temperature
Operating
MR-210 / MR-260
–20 to +55º Celsius
(–25 to +70ºC restricted operation)
–4 to +131º Fahrenheit
(–13 to +158ºF restricted operation)
MR-270
0 to +55º Celsius
(0 to +70ºC restricted operation)
32 to +131º Fahrenheit
(32 to +158ºF restricted operation)
Storage &
Transport
–40 to +85º Celsius
–40 to +185º Fahrenheit
Humidity
Operating
5 to 95% relative humidity
Storage & Transport
5 to 95% relative humidity
Altitude
Operating
2000 m / 70 kPa
Reliability prediction
(MTBF)
Bellcore
RQGR at 40°C
MR-210
203 000 hours
MR-260
218 000 hours
MR-270
139 000 hours
Enclosure
Pressed steel
Dimension W x H x D
MR-210 / MR-260
173 x 36 x 119 mm
6.8 x 1.4 x 4.7 inches
MR-270
210 x 41 x 150 mm
8.3 x 1.6 x 5.9 inches
Weight
MR-210 / MR-260
0.49 kg
MR-270
0.9 kg
Degree of protection
IEC529
Enclosure
IP 40
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail or flat on
level surface