Westermo DDW-226 User Manual
Page 14
14
6642-22402
Ethernet TX
Electrical specification
IEEE std 802.3. 2005 Edition
Data rate
10 Mbit/s or 100 Mbit/s, manual or auto
Duplex
Full or half, manual or auto
Circuit type
TNV-1
Transmission range
Up to 150 m with CAT5e cable or better
Isolation to
All other
Connection
RJ-45 auto MDI/MDI-X
Shielded cable
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails.*
Conductive housing
Yes
Number of ports
4
* To minimise the risk of interference, a shielded cable is recommended when the cable is located
inside 3 m boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and
connected to this port.
SHDSL
Electrical specification
ITU-T G.991.2 Annex B
Data rate
192 kbit/s to 15.3 Mbit/s
Protocol
EFM according to IEEE 802.3-2005
Transmission range
According to ITU-T G.991.2 depending on line quality
Isolation to
All other
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Shielded cable
Not required
Number of ports
2
RS-232
Electrical specification
EIA RS-232
Data rate
300 bit/s – 115.2 kbit/s
Data format
7 or 8 data bits, odd/even/none parity, 1 or 2 stop bits
Protocol
Transparent, optimised by packing algorithm
Circuit type
SELV
Transmission range
15 m / 49 ft
Isolation to
Power, DSL, Ethernet
Galvanic connection to
USB, Console
Connection
RJ-45
Shielded cable
Not required
Conductive housing
Yes