Operation

'EasySatSystemWP' must be started by the user. The command to start ‘EasySatSystemWP’ has the fol-
lowing format:
<easysatsystem_dir>/EasySatSystemWP [/L:]
The optional argument /L indicates that statistics data should be collected. The number must be in
the range 4..120. This number specifies the sampling interval for the statistics data in seconds; (approxi-
mately) every n1 seconds a snapshot of the busy status of each card is taken and written at program ter-
mination to the statistics file Stat.txt in <easysatsystem_data_dir> or in the directory
specified by the environment variable EASYSATSYSTEM_DATA_DIR if it is set. If this argument is not pre-
sent, or n1 is not in the range 4..120, no statistics data will be collected. A sampling interval specified in
the configuration file EasySATSystemWP.ini has precedence over the value passed as argument on the
command line. Absence of both parameters indicates that no statistical data has to be collected.
After starting ‘EasySatSystemWP’, a new window appears on the display, showing one line of status in-
formation for each correctly configured W-PCI or W-PCIe card, as well as the specified sampling interval,
and MES Id watch-list. The maximum number of cards is fixed to maxN=10.
For each configured card the following information is shown:

Column heading

meaning

Number

This is the global number of the card within the scope of the coordinated cards;

range: 1..maxN

SAT Mode

The SAT mode configured on this card

Computer Name or IP Address

Address of the PC containing this card; can be the (dotted) IP address or the

computer name; maximum length 30 characters

Serial #

Serial number of this card

Op Status

Operational status of the card, this can be:
'Not Connected': the PC containing this card is not under control of

‘EasySatSystemWP’
'Host Connected' (transient): the PC has answered to ‘EasySatSystem’ and an-

nounced all its cards
'Card Ready' (transient): the card has answered
'Mode Running': the mode was set on the card
'Busy Session': the card is monitoring a SAT session

MESId

If Op Status is ' Busy Session', this is the forward MES Id of the terminal being

in the monitoring session, otherwise this field is empty

Service

If Op Status is ' Busy Session', this is the service being monitored, otherwise

this field is empty

The term ‘transient’ means that this state may last only a very short time, and is therefore possibly not
visible for the user.
If a configured card is not shown at all, then there must be an error in the respective card’s specification
in the EasySATSystem.ini file.
Pressing the Exit button will terminate the program, as well as pressing the Close button in the window
frame.
Note:

At start-up, 'EasySatSystemWP' does not automatically synchronize with the operational status of
the cards. That means if a card is already in a session, this is not shown. Only at the next status
change of the card, the Op Status field will display the correct status.

It can take some time until the program has properly terminated after pressing Exit or Close.

The system does not check if more than one instance of 'EasySatSystem' is coordinating the same
card(s). So make sure to start this program with the same cards configured only once.

It is recommended to manually control from time to time the signal level settings at the different
cards under the control of ‘EasySatSystemWP’, also when ALS is enabled.

Error Handling


'EasySatSystemWP' tries to connect configured, but not connected cards approximately every 30 seconds.
All cards not connected are shown in the Op Status field accordingly.