ATEX Directive: Watson-Marlow 700 series pumpheads User Manual

6

For each application it is strongly recommended that tube life should be determined
by trials, prior to installation in a hazardous environment. If this is not possible, or
if there is any doubt in terms of tube life then the following hazards should be rec-
ognised before installing a pump in a potentially explosive atmosphere:

Chemical reaction between pumped fluid and pump materials - the

materials of construction are listed in Section 10

Pumped fluid can be ignited by surface temperature of rollers - all

Watson Marlow’s ATEX equipment has been rated as T4 (mean-

ing that even under worst-case operating conditions the maximum

surface temperature will not exceed 135C)

Factors influencing tube life
Normal tube fatigue - dependent on tube size and material

Incorrect tube loading - see 701R manual (PB0230) for guidance

Excess working pressure - see Section 4 “Operating parameters”

Chemical incompatibility - a table of tubing compatibility can be

found on http://www.watson-marlow.com/wmb-gb/p-chem-a.htm.

Immersion kits are available from Watson-Marlow for testing.

7 Tube life

A number of factors contribute to the life of the tubing: