beautypg.com

Adjustment of the pumphead rollers, Installation – Watson-Marlow 603S/R User Manual

Page 8

background image

Page 8

Adjustment of the pumphead rollers

The two spring loaded rollers compensate for tolerance variations in the wall

thickness of tubing, eliminating the manual adjustment normally required by

peristaltic pumps, and, in general, there should be no need for the gap setting

between the rollers and track to be adjusted.
Should it ever appear that the roller arms are not equally adjusted, the original

factory setting of 5.2mm can easily be restored. There is an adjustment screw

on each of the two roller arms. Turn each screw anticlockwise until both

rollers are just in contact with the track, and then turn each screw clockwise

by five turns. Correct and equal adjustment is important. Over-occlusion will

reduce tube life. Under-occlusion will reduce pumping efficiency.

Installation

The 603S drives are fitted with pumpheads which incorporate an electrical

"safe-guard" isolation switch which will disable the drive when the pumphead

is opened or removed. To fit the pumphead first remove the cover from the

cased drive. Pass the pumphead guard switch wires through the front panel

of the drive and connect to the terminal block as shown below.

Red

Yellow

Black

Red

Blue

White

603R
Pumphead

603S

Drive

Fit the track over the drive spindle and locating boss. Tighten the track
retaining screws. After checking that the drive spindle has been completely
degreased, slide the rotor into position. The rotor is attached to the drive
spindle via a split collet, and it is important that the rotor retaining screw is
fully tightened a torque of 13Nm to prevent slipping when the pump is being
used.
To remove the track, remove any tubing from the pumphead. Loosen the
rotor securing bolt and give the rotor/bolt a sharp tap to free the collet.
Release the collet, and withdraw the rotor from the shaft. Loosen the two
track securing screws and pull the track clear.