Warning Codes

In the event of a warning, the inverter display will flash. The last warning to occur is stored in parameter P931.

Warning

Cause

Corrective action

002

Current limit active

Check whether the motor power corresponds to the inverter power.
Check that the cable length limits have not been exceeded.
Check motor cable and motor for short-circuits and earth faults.
Check whether the motor parameters (P080-P085) correspond with the motor
being used.
Check the stator resistance (P089).
Increase the ramp start up time (P002).
Reduce the boost set in P078 and P079.
Check whether the motor is obstructed or overloaded.

003

Voltage slip active

004

Slip limit exceeded.

005

Inverter overtemperature

Check that the ambient temperature is not too high.

(heatsink)

Check that the air inlet and outlet are not obstructed.
Check that the inters integral fan is working.

006

Motor over-temperature

Check if motor is overloaded.
Check that P087 has not been set to 1 without a PTC being connected.

010

Use power supply- current limit

018

Auto re-start after fault (P018)
is pending

WARNING: The inverter may start at any time.

075

Braking resistor-hot

System Parameters

Note: In the following parameter table:

l

Indicates parameters that can be changed during operation.

¶¶¶

Indicates that the value of this factory setting depends on the rating of the inverter.

If parameters are changed accidentally, all parameters can be reset to their default values by setting parameter P944 to 1 and
then pressing P.

Parameter Function

Default

Your setting

P001

Operating dis[lay

-

P001

l

Dis[lay mode

0

P002

l

Ramp up time (seconds)

10.00

P003

l

Ramp down time (seconds)

25.00

P004

l

Smoothing (seconds)

0.0

P005

l

Digital frequency setpoint (Hz)

50.00

P006

Frequency setpoint source selection

1

P007

Keypad control

0

P009

l

Parameter protection setting

0

P011

Frequency setpoint memory

0

P012

l

Minimum motor frequency (Hz)

0.00

P013

l

Maximum motor frequency (Hz)

50.00

P014

l

Skip frequency 1 (Hz)

0.00

P015

l

Automatic restart after mains failure

0

P016

l

Start on the fly

0

P017

l

Smoothing type

1

P018

l

Automatic restart after fault

0

P019

l

Skip frequency bandwidth (Hz)

2.00

P020

Flying start ramp time (seconds)

25.0

P021

l

Minimum analogue frequency (Hz)

0.00

P022

l

Maximum analogue frequency (Hz)

50.00

P051

Selection control function (DIN1 - terminal 5) fixed

1

frequency 3 or binary fixed frequency bit 0

P052

Selection control function (DIN2 - terminal 6) fixed

2

frequency 2 or binary fixed frequency bit 1