Installation

electrolux 7

EN

INSTALLATION

2-INSTALLATIONINSTRUCTIONS
Some installation systems require the

opening and removal of the metal grille

panel.
2.1 - Instructions for opening and

removing the metal grille panel

To open the grille panel, press inwardly

on the two slider catches at each side

of the grille panel and the grille will pivot

down.

To remove the metal grille, pull forward

on the right hand side so that the hin-

ge pin on the back of the grille will be

released from the slot in the side of the

casing.
2.2 - Wall cabinet fixing
a-Predrilled wall cabinet: fix the hood

onto the wall cabinet base panel using

the four screws .2 x 5 mm (supplied

with the fixing kit).

It is not necessary to open the metal

grille.

b-No predrilled wall cabinet:

b.1-If the hood is provided with a pa-

per fixing template, follow the instruc-

tions.

b.2-If the hood is not provided with

a paper fixing template, position the

hood on the wall cabinet base panel

and pilot drill the 3.5 x 16 mm screws

(not supplied with the fixing kit) from

the inside onto the wood.

2.3-Wallmounting
a-Drill two Ø 8 mm holes on the wall us-

ing the paper template, insert two rawl

plugs and two .2 x ,mm screws

leaving 5 mm untightened. Open the

metal grille panel, hook the hood on

and fully tighten the screws.

b-If the hood is not provided with a pa-

per fixing template, drill two Ø 8mm

holes (see draw.), insert the plugs and

screws, proceeding as directed under

paragraph a.

c-For wall mounting using wallbrackets

(optional), follow the instructions of

the fixing template.

d-Pay attention to the safety regulation

of point 1.6.

2.4 - Choice of operating mode

a-Evacuationmode

To check that the hood is set up for

evacuation, open the grille panel and

make sure that the conversion lever or

the change-over knob on the centrifugal

unit is in the DUCTING position. The

charcoal filter is not required.

For ducting to the outside, the hood is

supplied with a rear and top outlet. A

flange spigot of 100 mm diameter (120

mm in certain models) is usually fitted

on the top outlet and a blanking plug on

the rear outlet. If you choose to duct the

hood from the rear of the casing, you

should invert the position of the flange

and of the blanking plug. Pay attention

to the safety regulation 1.1.

b-Internalrecirculationmode

To check that the hood is set up for

recycling, open the grille panel and

make sure that the conversion lever or

the change-over knob on the centrifugal

unit is in the RECYCLING position. The

charcoal filter is to be fitted. To fit the

charcoal filter, support the filter with one

hand and turn the thumb screw through

the centre of the charcoal filter. If the

filter is of the interlocking type, turn the

filter clockwise. The hood can remain

connected to the outside.
2.5-Electricalconnectionand

workingtest
1-The safety measures 1.2, 1.3, 1. and

1.5 of paragraph 1 are to be strictly

observed.

2-Once the electrical connection has

been completed, check that the

worktop illumination, motor and

speeds work properly.