MAINTENANCE
29
Point
Action
To be carried out
Remark
1
Check the lubricant
level.
Before startup of the
pump and on a sched-
uled interval during oper-
ation.
Make sure that the lubri-
cant level is above the
minimum level line in the
inspection window.
If necessary refill the
lubricant. See also §
2
Check the pump head
for any leakage of lubri-
cant around the cover,
the brackets and the rear
of the pump head.
Before startup of the
pump and on a sched-
uled interval during oper-
ation.
See §
.
3
Check the gearbox for
any leakage.
Before startup of the
pump and on a sched-
uled interval during oper-
ation.
In case of leakage con-
sult your Bredel repre-
sentative.
4
Check pump for deviat-
ing temperature or
strange noises.
On a scheduled interval
during operation.
See §
.
5
Check rotor with integral
pressing shoes for
excessive wear.
When replacing the
pump hose.
See §
6
Internal cleaning of the
pump hose.
Cleaning of the system
or product change.
See §
7
Replacing pump hose.
Preventive, this means
after 75% of the hose life
of the first hose.
See §
8
Changing lubricant.
After every 2
nd
hose
change or after 5,000
service hours, whichever
comes first or after hose
rupture.
See §
9
Replacing seal ring.
If necessary.
See §
.