Replacing flash – VXL Instruments Itona C Series Thin Client - Service Manual User Manual
Page 11
Replacing Flash
7
4
Replacing Flash
To replace Flash:
1. Remove the power adapter, pedestal and side cover. For more information see, section
‘Removing the Pedestal and Side Cover’ on page 3.
2. Apply isopropyl alcohol on the glue holding the flash, pull the glue out using the nose pliers.
Figure 7: Remove Glue from the Flash Holder
3. Gently pull the IDE flash up from the socket, as shown in Figure 8.
Figure 8: Flash
4. Place the new flash in the free socket and press it downwards.
Note: Ensure that the new flash is of the same dimensions as the previous one and has the
correct software image installed on it.
5. Fix the top cover, pedestal and power adapter. For more information see, Fixing on page 4.