Verilink PRISM 3111 (CG) Configuration/Installation Guide User Manual
Page 3

3111/3112 Menutree
T1 Net Params
Framing: ESF, D4
Ln Code: B8ZS, AMI
LBO: 0 dB,
−
7.5 dB,
−
15 dB,
−
22.5 dB
PRM: Dis, En
Zero Sup: En, Dis
Timing: Net, T1-DTE, Port 1, Int
Rem Comm: 1–24
T1 DTE Params
Framing: ESF, D4
Ln: B8ZS, AMI
Level: 0–110 ft, 111–220 ft, 221–330 ft, 331–440 ft,
441–550 ft, 551–660 ft, > 660 ft
Chan Assign: Ch. 1–Ch. 24: Idle, Thru, T + Sig
Port 1 Params
Rate: N
×56Κ,
N
×64Κ
Port 2 Params
Ch asign: Cont., Alt
Start Chan: 1–24
56/64
×
N:
×
1 = 56/64
×
9 = 504/576
×
17 = 952/1088
×
2 = 112/128
×
10 = 560/640
×
18 = 1008/1152
×
3 = 168/192
×
11 = 616/704
×
19 = 1064/1216
×
4 = 224/256
×
12 = 672/768
×
20 = 1120/1280
×
5 = 280/320
×
13 = 728/832
×
21 = 1176/1344
×
6 = 336/384
×
14 = 784/896
×
22 = 1232/1408
×
7 = 392/448
×
15 = 840/960
×
23 = 1288/1472
×
8 = 448/512
×
16 = 896/1024
×
24 = 1344/1536
Clock: Int, Ext, Oversamp
Invert: No, Yes
CTS: Force T, Force F, Int
DSR: Force T, Force F, Int
DCD: Force T, Force F, Int
LL: Dis, En
RL: Dis, En
V54: Dis, En
DTR Alrm: Dis, En
DBU Params
State: Disabled, Enabled, Active, Connecting, Disallow,
Dialing, Disconn, Testing, Tst Pass, Tst Fail
Cmd: Disable, Enable, En Daily, Activate, Test
Activator1:
LOS UAS
AIS
Activator 2:
ES
OOF
BPV
SES RAS
Any
Mode: Master, Slave
Security: Dis, En
DBU Password*
DTR Dial: Dis, En
Dial String*
Init String*
Reset String 1–5*
Activation Periods
TCP/IP Params
LAN Con
TokR: Tok Spd: 4 MHz, 16 MHz
Unit IP Addr*
Enet
Subnet Mask*
SLIP
Router IP Addr*
Fltr 1–8 IP Addr*
Reset LAN: No, Yes
SNMP Params
SETs: En, Dis
Manage Ports
Element ID*
Trap 1–6 IP Addr*
SUPV Prt Parms
COA Con: Dis, Dial, Dirct
Read Community*
Prim Dial Str*
Write Community*
Sec Dial Str*
Sys Contact*
Init Dial Str*
Sys Name*
Dis Conn Str*
Sys Location*
SLIP Prt Parms
SLIP Con: Dis, Dial, Dirct
Prim Dial Str*
Sec Dial Str*
Init Dial Str*
Dis Conn Str*
Comp SLIP: Auto, Dis, En
Main Menu
Alarms
Net: LOS, OOF, RAI, AIS, ERR, Ok, TST, UAS, DBA, DBF
DTE: Ok, T1D, P1, P2
Reset Tmr: 000–900
ES
SES
LOS
OOFS
UAS
RAS
AISS
BPVS
DLOS
PLS
Reset Alms: No, Yes
Performance
Targt: User, Net; User, DTE; Tlco, Net; Tlco, DTE
15 Min Perform
ES
SES
CRCS
AISS
24 Hr Perform
UAS
LOFC
OOFS
RAS
30 Day Perform
BES
CSS
LOSS
BPVS
Reg
Reset: No
Yes: Verification Continue?: No, Yes
Maintenance
T1 Net Loops
Far PLB: None, LpUp, LpDn
Far LLB: None, FLpUp, FLpDn, ULpUp, ULpDn
Net PLB: None, LpUp, LpDn
Net LLB: None, LpUp, LpDn
DTE MLB: None, LpUp, LpDn
T1 DTE Loops
Net MLB: None, LpUp, LpDn
DTE LLB: None, LpUp, LpDn
Port 1 Loops
Near: None, LpUp, LpDn
Port 2 Loops
Far: None, LpUp, LpDn
BERT Function
Pattern: QRSS, 63, 511, 2047, 2
15
, 2
20
,
2
23
, 1:8, 3:24, Alt, Clear
BERT:
None, Idle, T1 Net, T1 DTE, 1 Net,
1 DTE, 2 Net, 2 DTE, Ch. 1–24
Sync: No Test, No Sync, In Sync
Time: HH:MM:SS
BitErr: 0–999999
ErrSec: 0–999999
SynLos: 0–999999
Reset: No, Yes
Configuration
Utilities
SUPV: 1.2K, 2.4K, 9.6K, 19.2K
SLIP: 1.2K, 2.4K, 9.6K, 19.2K
Date: MM/DD/YY
Time: HH:MM:SS
Set Password*
Maint Rst:
No
Yes: Verification Continue?: No, Yes
Fact Rst:
No
Yes: Verification Continue?: No, Yes
Contrast: 0–15
Download: No
19.2K, 38.4K, 57.6K: Verification Continue?: No, Yes
* An underscore appears under
the character to be entered or
modified.
Press the EXIT button on the last
character to enter the value and
return to the previous screen.
Press the SCROLL button to
increment the characters (a–z,
A–Z, 0–9, special characters).
Press the SELECT button to
accept the current value and
move the cursor right.
Two three-digit values separated by a delimiter
(xxx /xxx) display the Current and Threshold
alarm values respectively. These values range
from 000 to 900. An asterisk (*) to the left of
these values indicates that the Current value
exceeds the Threshold value. Pressing SELECT
on a displayed alarm allows editing its
threshold parameters. PLS displays only the
Current count and cannot be modified.
The number of
events in the
specified period.