Verilink PRISM 3000 (CG) Configuration/Installation Guide User Manual
Prism 3000 configuration guide

PRISM 3000 Configuration Guide
T
R
A
N
S
P
O
R
T
®
Customer Location:
________________________________________
Circuit ID:
________________________________________
Date:
______ / ______ / ______
T1 NET CONFIGURATION
Framing Type:
ESF D4
Line Coding:
AMI B8ZS
Line Build Out:
0 dB -7.5 dB -15 dB -22.5 dB
Timing:
INTERNAL NETWORK T1 DTE STATION
PORT 1 PORT 2 PORT 3 PORT 4
Station Input Timing:
1.544 MHz N x 56K N x 64K
(Timing must be set to ‘Station’ in ‘Timing menu’)
Station Timing:
______
Enter a number from 1 to 24 to select the
‘N’ multiplier for the ‘Station Input Timing’ menu.
Zero Suppression:
ENABLE DISABLE
PRM Enable:
ENABLE DISABLE
Alarm Thresholds:
ALARM RESET:___ ES:___ SES:___
(enter # of seconds)
LOSS:___
OOFS:___ UAS:___
RAS:___ AISS:___ BPVS:___
T1 DTE CONFIGURATION (Optional)
Framing Type:
ESF D4
Line Coding:
AMI
B8ZS
DSX Level (feet):
0-110 111-220 221-330 331-440
441-550 551-660 > 660
Channel Assignment:
IDLE THRU REM
COM PORT 1
PORT 2 PORT 3 PORT 4
DTE PORT 1
Port Rate Multiplier:
N x 64K N x 56K DISABLE
Port Rate:
______
Enter a number from 0 to 24 to select the
‘N’ multiplier for the ‘Port Rate Multiplier’ menu.
Starting Channel #:
______
Enter a number from 1 to 24
.
DS0 Channel Assign:
CONTIGUOUS ALTERNATING
Port Transmit Clock:
INTERNAL EXTERNAL OVERSAMPLED
Invert Data:
NO YES
CTS Control:
INTERNAL FORCE TRUE FORCE FALSE
DSR Control:
INTERNAL FORCE TRUE FORCE FALSE
DCD Control:
INTERNAL FORCE TRUE FORCE FALSE
V.54 Loop:
ENABLE DISABLE
RS232 Port Rate:
NONE SYNCHRONOUS 1200 2400
(optional)
4800 9600 14400 19200 28800
38400 48000 56000 64000
DTE PORT 2
Port Rate Multiplier:
N x 64K N x 56K DISABLE
Port Rate:
______
Enter a number from 0 to 24 to select the
‘N’ multiplier for the ‘Port Rate Multiplier’ menu.
Starting Channel #:
______
Enter a number from 1 to 24
.
DS0 Channel Assign:
CONTIGUOUS ALTERNATING
Port Transmit Clock:
INTERNAL EXTERNAL OVERSAMPLED
Invert Data:
NO YES
CTS Control:
INTERNAL FORCE TRUE FORCE FALSE
DSR Control:
INTERNAL FORCE TRUE FORCE FALSE
DCD Control:
INTERNAL FORCE TRUE FORCE FALSE
V.54 Loop:
ENABLE DISABLE
DTE PORT 3
Port Rate Multiplier:
N x 64K N x 56K DISABLE
Port Rate:
______
Enter a number from 0 to 24 to select the
‘N’ multiplier for the ‘Port Rate Multiplier’ menu.
Starting Channel #:
______
Enter a number from 1 to 24
.
DS0 Channel Assign:
CONTIGUOUS ALTERNATING
Port Transmit Clock:
INTERNAL EXTERNAL OVERSAMPLED
Invert Data:
NO YES
CTS Control:
INTERNAL FORCE TRUE FORCE FALSE
DSR Control:
INTERNAL FORCE TRUE FORCE FALSE
DCD Control:
INTERNAL FORCE TRUE FORCE FALSE
V.54 Loop:
ENABLE DISABLE
RS232 Port Rate:
NONE SYNCHRONOUS 1200 2400
(optional)
4800 9600 14400 19200 28800
38400 48000 56000 64000
DTE PORT 4
Port Rate Multiplier:
N x 64K N x 56K DISABLE
Port Rate:
______
Enter a number from 0 to 24 to select the
‘N’ multiplier for the ‘Port Rate Multiplier’ menu.
Starting Channel #:
______
Enter a number from 1 to 24
.
DS0 Channel Assign:
CONTIGUOUS ALTERNATING
Port Transmit Clock:
INTERNAL EXTERNAL OVERSAMPLED
Invert Data:
NO YES
CTS Control:
INTERNAL FORCE TRUE FORCE FALSE
DSR Control:
INTERNAL FORCE TRUE FORCE FALSE
DCD Control:
INTERNAL FORCE TRUE FORCE FALSE
V.54 Loop:
ENABLE DISABLE
SNMP CONFIGURATION (Optional)
Unit I.P. Address:
________ . ________ . _______
Router I.P. Address:
________ . ________ . _______
Trap I.P. Address:
________ . ________ . _______
Read Community:
_____________________________
Write Community:
_____________________________
System Contact:
_____________________________
System Name:
_____________________________
System Location:
_____________________________
DIAGNOSTICS
T1 Network Loop:
NONE LOOP
FAR UNLOOP
FAR PLB
LLB NET
MLB DTE
MLB
T1 DTE Loop:
NONE LLB
Port ___ Loop:
NONE NEAR SEND LOOP SEND
UNLOOP
BERT Function:
BERT Port:
NONE NETWORK T1
DTE PORT
1
PORT
2 PORT
3 PORT
4
BERT Channel:
ALL IDLE CHANNEL
____
(from 1 to 24)
BERT Pattern:
1 in 8 3 in 24 ALT CLEAR QRSS 63
511 2047 2
15
-1 2
20
-1 2
23
-1
BERT Direction:
TOWARD NETWORK TOWARD DTE
SYSTEM UTILITIES
Edit Password:
____________________
(up to 10 characters)
NMS Address:
__________
(select a number from 1 to 250)
NMS Bit Rate:
19200 9600 4800 2400 1200
Supv Bit Rate:
19200 9600 4800 2400 1200
Boot Mode:
LOCAL NMS
Alarm Cut Off:
DISABLE ENABLE
Remote Link:
FDL NONE CHANNEL ___
(from 1 - 24)
Call on Alarm:
Primary #:
____________________
(up to __ characters)
Secondary #:
____________________
(up to __ characters)
Element ID:
____________________
(up to 29 characters)
Alarm Notification:
OFF DIRECT DIAL DIAL NMS