beautypg.com

Trouble shooting guide, Problem, Cause correction – Delta DTT2450 User Manual

Page 13

background image

13- ENG

A04032

TROUBLE SHOOTING GUIDE

PROBLEM

Engine will not
start (see Engine
Manual for
further engine
troubleshooting)

No or low
pressure
(initial use)

CAUSE

CORRECTION

No fuel.

Add Fuel.

Pressure builds up after two pulls on
the recoil starter or after initial use.

Squeeze gun trigger to relieve
pressure.

Spark plug wire not attached.

Attach spark plug wire.

Spray wand not in high pressure.

See How to Use Spray Wand
instructions in the Operation
Section.

Low water supply.

Water supply must be at least 5
GPM @ 20 PSI.

Leak at high pressure hose fitting.

Repair leak. Apply sealant tape
if necessary.

Nozzle obstructed.

See Nozzle Cleaning instructions
in the Maintenance section.

Water filter screen clogged.

Remove and clean filter.

Air in hose.

Turn off the engine, then the
water source. Disconnect the
water source from the pump inlet
and turn the water source on to
remove all air from the hose.
When there is a steady stream of
water present, turn water source
off. Re-connect water source to
pump inlet and turn on water
source. Squeeze trigger to re-
move remaining air.

High pressure hose is too long.

Use high pressure hose under
100 feet.

Engine not primed

Push primer button three times

Throttle control lever is not in the
“Fast” position.

Move throttle control lever to the
“Fast” position.

Spray wand not in low pressure.

See How to Use Spray Wand
paragraph in the Operation
Section.

Chemical screen not in cleaning
solution.

Clean filter.

Chemical too thick.

Dilute chemical. Chemical should
be the same consistency as water.

Pressure hose is too long

Lengthen water supply hose
instead of high pressure hose.

Chemical build up in chemical
injector.

Have parts cleaned or replaced
by AWSC.

Will not draw
chemicals

Make sure end of chemical hose
is fully submerged into cleaning
solution.

Chemical filter clogged.