Wallmount installation, Using adhesive strips, Using screws – Verilink DDS Lite (34-00295.C) Product Manual User Manual
Page 12: Connections, Dds network connection, Using adhesive strips using screws, Network connection, Supplied materials

6
C
HAPTER
2: I
NSTALLATION
AND
C
ONFIGURATION
Supplied
Materials
The Multi-Rate DDS CSU/DSU is shipped from the factory
with the following standard equipment.
✦
external AC power supply
✦
reference manual
✦
adhesive strip
✦
phone cable
Wallmount
Installation
Using Adhesive Strips
1 Select a place close to a 115 VAC outlet with clearance for the
signal and power cables. The indicators and switches should be
easily accessible.
2 Verify the mounting surface is clean.
3 Cut the adhesive strip to the desired length and affix the backing
of one piece to the underside of the unit.
4 Attach the other adhesive strip to the piece on the underside of
the unit.
5 Remove the backing to expose the sticky surface.
6 Press the underside of the unit firmly against the selected place.
Using Screws
1 Select a place close to a 115 VAC outlet with clearance for the
signal and power cables. The indicators and switches should be
easily accessible.
2 Vertically place two #6 screws 3-13
⁄
32 inches apart at the
selected place. Leave the screws out about an eighth of an inch.
3 Place the upright unit over the screws until the holes engage and
slide the unit down until it locks.
Connections
The Multi-Rate DDS CSU/DSU has three interface connectors:
an RJ- 48C DDS network connector, a 3-pin power connector,
and an RS-232 connector.
DDS
Network
Connection
The network DDS facility
interface is a standard
RJ- 48C (8 -pin) modular
jack with the following
pinout.
Table 2-1 DDS Network Connection
Pin
Assignment
1
Network Transmit Out
2
Network Transmit Out
3 – 6
Not Used
7
Network Data In
8
Network Data In