beautypg.com

Performance, Blower performance – Ducane RGE13 User Manual

Page 3

background image

Residential Packaged Unit Gas / Electric

Residential Packaged Unit Gas / Electric

Performance

Model

Cooling

Heating

BTUH

SEER

EER

S/T

CFM

Input

BTUH

Output

BTUH

Efficiency

AFUE

Temp

Rise

Range °F

RGE13A24050(L)P

22,800

13.0

11.0

0.74

800

50,000

40,000

80%

30 - 60

RGE13A24075(L)P

75,000

60,000

35 - 65

RGE13A30050(L)P

28,000

13.0

11.0

0.76

1050

50,000

40,000

80%

30 - 60

RGE13A30075(L)P

75,000

60,000

35 - 65

RGE13A36075(L)P

34,000

13.0

11.0

0.71

1200

75,000

60,000

80%

35 - 65

RGE13A36100P

100,000

80,000

45 - 75

RGE13A42075(L)P

40,000

13.0

11.0

0.75

1400

75,000

60,000

80%

30 - 60

RGE13A42100(L)P

100,000

80,000

40 - 70

RGE13A48100(L)P

46,000

13.0

11.0

0.75

1600

100,000

80,000

80%

40 - 70

RGE13A48125P

125,000

100,000

45 - 75

RGE13A60100(L)P

56,000

13.0

11.0

0.72

1800

100,000

80,000

80%

40 - 70

RGE13A60125P

125,000

100,000

45 - 75

Blower Performance

Model

Blower

Tap*

(1 - 5)

CFM @ ext. Static Pressure in in. wc without filter, dry coil

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

RGE13A24***(L)P

1

500

480

420

340

290

240

---

---

2

830

790

760

710

640

600

560

520

3

1020

980

940

890

850

810

760

700

RGE13A30***(L)P

1

680

600

530

480

440

380

---

---

2

1080

1040

1000

960

930

890

840

780

3

1120

1090

1040

1010

980

930

890

840

RGE13A36***(L)P

1

760

680

600

550

490

---

---

---

2

1250

1210

1180

1130

1090

1060

1010

960

3

1370

1330

1280

1250

1210

1170

1120

1040

RGE13A42***(L)P

1

860

780

710

660

600

560

---

---

2

1460

1400

1340

1280

1230

1180

1140

1100

3

1600

1560

1500

1450

1400

1320

1230

1150

RGE13A48***(L)P

1

970

890

820

780

740

680

---

---

2

1680

1640

1590

1540

1450

1330

1260

1180

3

1890

1820

1730

1620

1540

1430

1300

1210

RGE13A60***(L)P

1

1200

1130

1070

990

930

860

-

-

2

1870

1840

1800

1760

1700

1650

1600

1550

3

2010

1970

1930

1890

1850

1810

1760

1700

Add .10 Duct Static for Downflow CFM

* Tap 1 - Fan Only
Tap 2 - Low Static Cooling
Tap 3 - High Static Cooling

Taps 4 & 5 designed for Heating
mid point temperature rise @: Tap 4 - Nominal .2 ESP

Tap 5 - Nominal .5 ESP

- Page 3 -