Model CBM-2, Counterbore Module
92-0177 : Rev. 140226
MAINTENANCE
All components should be cleaned and coated with a light film of oil prior to storage.
Use a clean, non-detergent oil, preferable SAE 10 (90 SSU or lighter) or oil which is
specified for the air motor.
If the C’bore Module is operated in such a way that the Module collects chips
or debris near the tool holder, the C’bore Module should be cleaned after
each cutting operation.
DAILY
Wipe the unit down and spray with rust preventative under severe humidity
conditions.
Visually inspect for loose screws, missing bolts, or damage due to impact.
Tighten or replace screws or other parts as required.
Contact Tri Tool Inc. if a major repair is required.
MONTHLY
Thoroughly clean and lubricate the Feed Screw and the Boring Bar.
Feed the Boring Bar out of the Tool Bracket.
With a clean, dry rag, thoroughly wipe down the Boring Bar and the Feed Screw. Be
sure that all old lubrication, chips, and dirt are completely removed.
Lubricate the Feed Screw and Boring Bar with a light machine oil.
Reassemble the Boring Bar into the Tool Bracket.