KSR-EJK expansion joint kit is designed to allow cable to cross
a concrete expansion or construction joint. When installed, the
kit will allow normal expansion and contraction of the substrate
without straining or damaging the cable.

Installation Precautions . . .
• The kit instructions should be used in conjunction with installation

instructions for the heating cable and other accessory items.

• Keep ends of heating cable and kit components dry before and

during installation.

KSR-EJK

2

Item

Quantity

Description

Split Corrugated Tubing

2

Self Vulcanizing Tape

Kit Contents . . .

1.

Insert cable into corrugated tubing through split in tubing. Rotate
corrugated tubing until split is facing downward.

Split at Bottom

Corrugated Tubing

KSR Cable

Corrugated Tubing

KSR Cable

Self Vulcanizing Tape

2.

Wrap self vulcanizing tape around heating cable and each end of split
corrugated tubing.

75mm

(3”)

50mm

(6”)

200mm

(8”)

50mm

(2”)

Sand Fill

Concrete

Reinforcement

Bar

Expansion Joint

Installation Instruction . . .

3.

Typical heating cable layout should be routed to avoid crossing
expansion, crack, or construction joints. If crossing a joint is required,
the cable and protective tube should be looped beneath the joint, with
the cable attached to the concrete reinforcing bar at each end.

Tie Wrap