beautypg.com

Fak-7 – Thermon FAK-7 User Manual

Page 2

background image

FAK-7 Seal Kit is designed to protect the thermal insulation and
seal tubing bundle ends. When installed, it should allow nor-
mal expansion and contraction of the tubing (and heat trace, if
included) without straining or damaging the overjacket.

Installation Precautions . . .
• These instructions should be used in conjunction with instructions

for the electrical heat tracing and any other accessory items being
installed.

• Keep ends of bundle, heat tracing (if any), and kit components

dry before and during installation.

FAK-7

1

2

Item

Quantity

Description

1

1

Self Vulcanizing Tape

2

3

RTV Tube

Kit Contents . . .

2.

Deburr end of tubing and make necessary field installation connections. If

tubing is electrically heat traced, make-up end termination and/or power

connection per instructions included with the appropriate termination

kit. (order separate from the FAK-7)

3.

Liberally apply RTV sealant to tubing bundle insulation.

4.

While removing the clear backing from tape, wrap end of tubing

bundle with self-vulcanizing tape. Start a minimum of 51mm (2”)

above the cut on the outer jacket and continue a minimum of 51mm

(2”) along the bare tubing. Overlap the tape at least 50%. If electrically

heat traced, it is recommended that the end termination be sealed

and placed inside the insulation or at the connection, to assure no

moisture enters the bundle insulation.

Installation Instructions . . .

1.

Strip back insulation approximately 101mm (4”) from tubing bundle
end .

101mm

(4”)

Tubing Bundle

Jacket

Tubing

Electrical Heat Tracing

(if included)

Tube Fitting

by others

“ET” End Termination Boot

(if electrically heat traced)

RTV Sealant to cover

exposed thermal insulation

Self-Vulcanizing Tape

Remove clear backing

as tape is applied

51mm

(2”)

51mm

(2”)

Exposed Insulation

Material

The Heat Tracing Specialists

®

100 Thermon Dr.

PO Box 609

San Marcos, TX 78667-0609

Phone: 512-396-5801

Facsimile: 512-396-3627

1-800-820-

HEAT

www.thermon.com

In Canada call 1-800-563-8461

Specifications and information are subject to change without notice.

Form 50039-090